Lab-Measurement 3.920 Latest
Kwalitee Issues
- prereq_matches_use
-
List all used modules in META.yml requires
Error:
- JSON
- Lab::VISA
- Lab::VXI11
- Lab::Zhinst
- PDL::Graphics::Gnuplot
- USB::TMC
- meta_yml_has_provides
-
Add all modules contained in this distribution to the META.yml field 'provides'. Module::Build or Dist::Zilla::Plugin::MetaProvides do this automatically for you.
Modules
Name | Abstract | Version | View |
---|---|---|---|
Lab::Measurement | Temporary blocker module, errors out when used | 3.920 | metacpan |
Lab::Moose | Convenient loaders and constructors for L<Lab::Moose::Instrument>, L<Lab::Moose::Sweep>, L<Lab::Moose::DataFolder> and L<Lab::Moose::DataFile> | 3.920 | metacpan |
Lab::Moose::Catfile | Export custom catfile which avoids backslashes | 3.920 | metacpan |
Lab::Moose::Connection | Role for connections | 3.920 | metacpan |
Lab::Moose::Connection::Debug | Debug connection, printing / reading on terminal | 3.920 | metacpan |
Lab::Moose::Connection::HTTP | Connection with Http requests | 3.920 | metacpan |
Lab::Moose::Connection::IsoBus | Connection back end to the Oxford Instruments IsoBus | 3.920 | metacpan |
Lab::Moose::Connection::LinuxGPIB | Connection back end to the LinuxGpib library and kernel drivers | 3.920 | metacpan |
Lab::Moose::Connection::Mock | Mock connection, supplying instrument responses from a log file | 3.920 | metacpan |
Lab::Moose::Connection::Socket | Transfer IEEE 488.2 / SCPI messages over TCP | 3.920 | metacpan |
Lab::Moose::Connection::USB | Connection backend to USB Test & Measurement (USBTMC) bus | 3.920 | metacpan |
Lab::Moose::Connection::VISA | Connection back end to National Instruments' VISA library. | 3.920 | metacpan |
Lab::Moose::Connection::VISA::GPIB | GPIB frontend to National Instruments' VISA library. | 3.920 | metacpan |
Lab::Moose::Connection::VISA::USB | USB-TMC frontend to National Instruments' VISA library. | 3.920 | metacpan |
Lab::Moose::Connection::VISA::VXI11 | VXI-11 frontend to National Instruments' VISA library. | 3.920 | metacpan |
Lab::Moose::Connection::VISA_GPIB | compatiblity alias for VISA::GPIB | 3.920 | metacpan |
Lab::Moose::Connection::VXI11 | Connection backend to VXI-11 (Lan/TCP) | 3.920 | metacpan |
Lab::Moose::Connection::WWW | Connection with URL requests | 3.920 | metacpan |
Lab::Moose::Connection::Zhinst | Connection back end to Zurich Instrument's LabOne measurement control API | 3.920 | metacpan |
Lab::Moose::Countdown | Verbose countdown/delay with pretty printing of remaining time | 3.920 | metacpan |
Lab::Moose::DataFile | Base class for data file types | 3.920 | metacpan |
Lab::Moose::DataFile::Gnuplot | Text based data file ('Gnuplot style') | 3.920 | metacpan |
Lab::Moose::DataFile::Gnuplot::Compressed | Text based data file ('Gnuplot style'), auto-compressed | 3.920 | metacpan |
Lab::Moose::DataFile::Meta | YAML Metadata file | 3.920 | metacpan |
Lab::Moose::DataFile::Read | Read a gnuplot-style 2D data file | 3.920 | metacpan |
Lab::Moose::DataFolder | Create a data directory with meta data | 3.920 | metacpan |
Lab::Moose::Instrument | Base class for instrument drivers | 3.920 | metacpan |
Lab::Moose::Instrument::ABB_TRMC2 | ABB TRMC2 temperature controller | 3.920 | metacpan |
Lab::Moose::Instrument::AH2700A | Andeen-Hagerling AH2700A ultra-precision capacitance bridge | 3.920 | metacpan |
Lab::Moose::Instrument::AMI_430 | American Magnetics magnet power supply | 3.920 | metacpan |
Lab::Moose::Instrument::AdjustRange | Role for automatic adjustment of measurement ranges. | 3.920 | metacpan |
Lab::Moose::Instrument::Agilent33120A | Agilent 33120A 15MHz arbitrary waveform generator | 3.920 | metacpan |
Lab::Moose::Instrument::Agilent33210A | Agilent 33210A Arbitrary Waveform Generator, also as voltage source | 3.920 | metacpan |
Lab::Moose::Instrument::Agilent34410A | Agilent 34410A digital multimeter. | 3.920 | metacpan |
Lab::Moose::Instrument::Agilent34460A | Agilent 34460A TrueVolt series digital multimeter. | 3.920 | metacpan |
Lab::Moose::Instrument::AttoCube_AMC | 3.920 | metacpan | |
Lab::Moose::Instrument::Bluefors_Temp | Bluefors temperature control | 3.920 | metacpan |
Lab::Moose::Instrument::Cache | Device caching functionality in Moose::Instrument drivers | 3.920 | metacpan |
Lab::Moose::Instrument::Common | Role for common commands declared mandatory by IEEE 488.2 | 3.920 | metacpan |
Lab::Moose::Instrument::Cryomagnetics_4G | Cryomagnetics 4G superconducting magnet power supply | 3.920 | metacpan |
Lab::Moose::Instrument::DisplayXY | Display with y vs x traces Role for Lab::Moose::Instrument | 3.920 | metacpan |
Lab::Moose::Instrument::DummySource | Dummy YokogawaGS200 source for use with 'Debug' connection | 3.920 | metacpan |
Lab::Moose::Instrument::HP33120A | HP 33120A 15 MHz Arbitrary Waveform Generator, also as voltage source | 3.920 | metacpan |
Lab::Moose::Instrument::HP34410A | HP 34410A digital multimeter. | 3.920 | metacpan |
Lab::Moose::Instrument::HP34420A | HP 34420A nanovolt meter. | 3.920 | metacpan |
Lab::Moose::Instrument::HP3458A | HP 3458A digital multimeter | 3.920 | metacpan |
Lab::Moose::Instrument::HP83732A | HP 83732A Series Synthesized Signal Generator | 3.920 | metacpan |
Lab::Moose::Instrument::HP8596E | HP8596E Spectrum Analyzer | 3.920 | metacpan |
Lab::Moose::Instrument::HPE4400B | HP E4400B Series Spectrum Analyzer | 3.920 | metacpan |
Lab::Moose::Instrument::Keithley2000 | Keithley 2000 digital multimeter | 3.920 | metacpan |
Lab::Moose::Instrument::Keithley2400 | Keithley 2400 voltage/current sourcemeter. | 3.920 | metacpan |
Lab::Moose::Instrument::Keithley2450 | Keithley 2450 voltage/current sourcemeter. | 3.920 | metacpan |
Lab::Moose::Instrument::Keysight33600 | Keysight 33500/33600 series Function/Arbitrary Waveform Generator (work in progress) | 3.920 | metacpan |
Lab::Moose::Instrument::Keysight34470A | Keysight 34470A digital multimeter. | 3.920 | metacpan |
Lab::Moose::Instrument::KeysightB2901A | Agilent/Keysight B2901A voltage/current sourcemeter. | 3.920 | metacpan |
Lab::Moose::Instrument::KeysightDSOS604A | Keysight DSOS604A infiniium S-Series Oscilloscope. | 3.920 | metacpan |
Lab::Moose::Instrument::KeysightE3633E | Keysight E3633E voltage/current source. | 3.920 | metacpan |
Lab::Moose::Instrument::KeysightN9310A | Keysight N9310A Signal Generator | 3.920 | metacpan |
Lab::Moose::Instrument::Lakeshore340 | Lakeshore Model 340 Temperature Controller | 3.920 | metacpan |
Lab::Moose::Instrument::Lakeshore340::Helium3 | Lakeshore Model 340 Temperature Controller for Helium3 operation | 3.920 | metacpan |
Lab::Moose::Instrument::Lakeshore350 | Lakeshore Model 350 Temperature Controller | 3.920 | metacpan |
Lab::Moose::Instrument::Lakeshore372 | Lakeshore Model 372 Temperature Controller | 3.920 | metacpan |
Lab::Moose::Instrument::LinearStepSweep | Role for linear step sweeps used by voltage/current sources. | 3.920 | metacpan |
Lab::Moose::Instrument::Log | Role for Lab::Moose::Instrument connection logging. | 3.920 | metacpan |
Lab::Moose::Instrument::NanonisTramea | Nanonis Tramea | 3.920 | metacpan |
Lab::Moose::Instrument::OI_Common | Role for handling Oxfords Instruments pseudo-SCPI commands | 3.920 | metacpan |
Lab::Moose::Instrument::OI_ILM210 | Oxford Instruments ILM Intelligent Helium Level Meter | 3.920 | metacpan |
Lab::Moose::Instrument::OI_IPS | Oxford Instruments IPS Intelligent Power Supply | 3.920 | metacpan |
Lab::Moose::Instrument::OI_IPS::Strunk_3He | Example subclass with predefined field limits of a Oxford Instruments IPS | 3.920 | metacpan |
Lab::Moose::Instrument::OI_ITC503 | Oxford Instruments ITC503 Intelligent Temperature Control | 3.920 | metacpan |
Lab::Moose::Instrument::OI_Mercury::Magnet | Oxford Instruments Mercury magnet power supply | 3.920 | metacpan |
Lab::Moose::Instrument::OI_Triton | Oxford Instruments Triton gas handling system control | 3.920 | metacpan |
Lab::Moose::Instrument::ProStep4 | ProStep4 step motor | 3.920 | metacpan |
Lab::Moose::Instrument::RS_FSV | Rohde & Schwarz FSV Signal and Spectrum Analyzer | 3.920 | metacpan |
Lab::Moose::Instrument::RS_RTB2000 | Rohde & Schwarz RTB 2000 oscilloscope (work in progress) | 3.920 | metacpan |
Lab::Moose::Instrument::RS_SMB | Rohde & Schwarz SMB Signal Generator | 3.920 | metacpan |
Lab::Moose::Instrument::RS_ZNL | Rohde & Schwarz ZNL Vector Network Analyzer | 3.920 | metacpan |
Lab::Moose::Instrument::RS_ZVA | Rohde & Schwarz ZVA Vector Network Analyzer | 3.920 | metacpan |
Lab::Moose::Instrument::RS_ZVM | Rohde & Schwarz ZVM Vector Network Analyzer | 3.920 | metacpan |
Lab::Moose::Instrument::Rigol_DG5000 | Rigol DG5000 series Function/Arbitrary Waveform Generator | 3.920 | metacpan |
Lab::Moose::Instrument::Rigol_DSA815 | Rigol DSA815 Spectrum Analyzer | 3.920 | metacpan |
Lab::Moose::Instrument::SCPI::Display::Window | Role for the SCPI DISPlay:WINDow subsystem | 3.920 | metacpan |
Lab::Moose::Instrument::SCPI::Format | Role for SCPI FORMat subsystem. | 3.920 | metacpan |
Lab::Moose::Instrument::SCPI::Initiate | Role for the SCPI INITiate subsystem used by Rohde&Schwarz | 3.920 | metacpan |
Lab::Moose::Instrument::SCPI::Instrument | Role for SCPI INSTrument subsystem. | 3.920 | metacpan |
Lab::Moose::Instrument::SCPI::Output::State | Role for the SCPI OUTPut:STATe subsystem | 3.920 | metacpan |
Lab::Moose::Instrument::SCPI::Sense::Average | Role for the SCPI SENSe:AVERage subsystem | 3.920 | metacpan |
Lab::Moose::Instrument::SCPI::Sense::Bandwidth | Role for the SCPI SENSe:BANDwidth subsystem | 3.920 | metacpan |
Lab::Moose::Instrument::SCPI::Sense::Frequency | Role for the SCPI SENSe:FREQuency subsystem | 3.920 | metacpan |
Lab::Moose::Instrument::SCPI::Sense::Function | Role for the SCPI SENSe:FUNCtion subsystem | 3.920 | metacpan |
Lab::Moose::Instrument::SCPI::Sense::Function::Concurrent | Role for the SCPI SENSe:FUNCtion subsystem with support for concurrent sense | 3.920 | metacpan |
Lab::Moose::Instrument::SCPI::Sense::Impedance | Role for the HP/Agilent/Keysight SCPI SENSe:$function:IMPedance subsystem | 3.920 | metacpan |
Lab::Moose::Instrument::SCPI::Sense::NPLC | Role for the SCPI SENSe:$function:NPLC subsystem | 3.920 | metacpan |
Lab::Moose::Instrument::SCPI::Sense::Null | Role for the HP/Agilent/Keysight SCPI SENSe:$function:NULL subsystem | 3.920 | metacpan |
Lab::Moose::Instrument::SCPI::Sense::Power | Role for the SCPI SENSe:POWer subsystem | 3.920 | metacpan |
Lab::Moose::Instrument::SCPI::Sense::Protection | Role for the SCPI SENSe:$function:Protection subsystem | 3.920 | metacpan |
Lab::Moose::Instrument::SCPI::Sense::Range | Role for the SCPI SENSe:$function:RANGe subsystem. | 3.920 | metacpan |
Lab::Moose::Instrument::SCPI::Sense::Sweep | Role for the SCPI SENSe:SWEep subsystem | 3.920 | metacpan |
Lab::Moose::Instrument::SCPI::Source::Function | Role for the SCPI SOURce:FUNCtion subsystem | 3.920 | metacpan |
Lab::Moose::Instrument::SCPI::Source::Level | Role for the SCPI SOURce:(CURRent|VOLTage):Level commands | 3.920 | metacpan |
Lab::Moose::Instrument::SCPI::Source::Power | Role for the SCPI SOURce:POWer subsystem | 3.920 | metacpan |
Lab::Moose::Instrument::SCPI::Source::Range | Role for the SCPI SOURce:RANGe subsystem. | 3.920 | metacpan |
Lab::Moose::Instrument::SCPI::Unit | Role for SCPI UNIT subsystem. | 3.920 | metacpan |
Lab::Moose::Instrument::SCPIBlock | Role for handling SCPI/IEEE 488.2 block data | 3.920 | metacpan |
Lab::Moose::Instrument::SR830 | Stanford Research SR830 Lock-In Amplifier | 3.920 | metacpan |
Lab::Moose::Instrument::SignalRecovery7265 | Model 7265 Lock-In Amplifier | 3.920 | metacpan |
Lab::Moose::Instrument::SpectrumAnalyzer | Role of Generic Spectrum Analyzer for Lab::Moose::Instrument | 3.920 | metacpan |
Lab::Moose::Instrument::Synctek_MCL1_540 | Synctek MCL1-540 Lock-in Amplifier | 3.920 | metacpan |
Lab::Moose::Instrument::TBS1000C | Tektronix TBS 1000C series Oscilloscope. | 3.920 | metacpan |
Lab::Moose::Instrument::VNASweep | Role for network analyzer sweeps | 3.920 | metacpan |
Lab::Moose::Instrument::Yokogawa7651 | Yokogawa7651 voltage/current source. | 3.920 | metacpan |
Lab::Moose::Instrument::YokogawaGS200 | YokogawaGS200 voltage/current source. | 3.920 | metacpan |
Lab::Moose::Instrument::ZI_HDAWG | Zurich Instruments HDAWG Arbitrary Waveform Generator | 3.920 | metacpan |
Lab::Moose::Instrument::ZI_HF2LI | Zurich Instruments HF2LI Lock-in Amplifier | 3.920 | metacpan |
Lab::Moose::Instrument::ZI_MFIA | Zurich Instruments MFIA Impedance Analyzer. | 3.920 | metacpan |
Lab::Moose::Instrument::ZI_MFLI | Zurich Instruments MFLI Lock-in Amplifier | 3.920 | metacpan |
Lab::Moose::Instrument::Zhinst | Base class for Zurich Instruments device drivers | 3.920 | metacpan |
Lab::Moose::Plot | Frontend to L<PDL::Graphics::Gnuplot> | 3.920 | metacpan |
Lab::Moose::Stabilizer | Sensor stabilizer subroutine | 3.920 | metacpan |
Lab::Moose::Sweep | Base class for high level sweeps | 3.920 | metacpan |
Lab::Moose::Sweep::Continuous | Base class for continuous sweeps (time, temperature, magnetic field) | 3.920 | metacpan |
Lab::Moose::Sweep::Continuous::Magnet | Continuous sweep of magnetic field | 3.920 | metacpan |
Lab::Moose::Sweep::Continuous::Time | Time sweep | 3.920 | metacpan |
Lab::Moose::Sweep::Continuous::Voltage | Continuous sweep of voltage | 3.920 | metacpan |
Lab::Moose::Sweep::DataFile | Store parameters of datafile and its plots. | 3.920 | metacpan |
Lab::Moose::Sweep::Step | Base class for step/list sweeps | 3.920 | metacpan |
Lab::Moose::Sweep::Step::Frequency | Frequency sweep. | 3.920 | metacpan |
Lab::Moose::Sweep::Step::Magnet | Step/list sweep of magnetic field | 3.920 | metacpan |
Lab::Moose::Sweep::Step::Phase | Phase sweep. | 3.920 | metacpan |
Lab::Moose::Sweep::Step::Power | Power sweep. | 3.920 | metacpan |
Lab::Moose::Sweep::Step::Pulsedelay | Pulsedelay sweep. | 3.920 | metacpan |
Lab::Moose::Sweep::Step::Pulsewidth | Pulsewidth sweep. | 3.920 | metacpan |
Lab::Moose::Sweep::Step::Repeat | Repeat something (e.g. some sweep) N times | 3.920 | metacpan |
Lab::Moose::Sweep::Step::Temperature | Step/list sweep of temperature | 3.920 | metacpan |
Lab::Moose::Sweep::Step::Voltage | Voltage sweep. | 3.920 | metacpan |